28 Jul

5 Reasons Why Static Programs Fail

Why Static Programs Fail

On May 6, 1937, the German passenger airship LZ 129 Hindenburg caught fire and was destroyed, killing 36 people in front of national news cameras and effectively ending the Zeppelin flying experiment.

The Hindenburg was larger than 4 Goodyear blimps combined, or about as long as 2/3 the height of the Empire State Building.

It was rainy that day, and the mooring ropes dragged along the ground as the airship came down to dock in Manchester Township. The prevailing theory is that the wet dragging ropes generated a static charge that traveled up them onto the ship.

There the charge ignited the Hydrogen fuel and… boom. Once considered the future of air travel, flying airships would not be utilized, either commercially or for military use until the end of World War II.

All caused by a single spark.

Much like the Hindenburg disaster, your company’s program to control electrostatic discharge (ESD) can be toppled with a few small errors that blossom into larger problems if they aren’t properly accounted and planned for.

So today, let’s look at the 5 common reasons why your static control programs could fail.

Sure! We have ESD Protocols, Right?

Most companies that deal with sensitive electronics and circuit boards also require that their vendors, third party suppliers, and subcontractors have an ESD program in place. Often even before signing a contract, an engineer is sent in to audit the ESD practices. And from time to time they will do spot-checks to verify that those practices are still in place.

Some companies, in an effort to hold on to their contract or cut expenses, will simply throw together a minimum program that can be audited. It’s done as inexpensively as possible and often doesn’t have any true protocols – training, preventative maintenance, and enforcement fall by the wayside.

You’d never do that, right? Well, except…

This is Gonna Cost How Much?

Top management are always looking at ways to work more economically. Unfortunately, if they are not properly briefed on the importance of proper ESD protection protocols, they may see many aspects of the ESD program as expensive and possibly unnecessary.

This isn’t their fault, they just need to be better educated. Which may be your job. The fact is, the expense for good, well-developed ESD protection protocols is dwarfed by the cost to replace or repair non-functioning components, not to mention the company’s reputation.

Excellent ESD companies are led from the top down, with company leadership not only showing financial support for ESD preventative programs, but also making time to attend training themselves, praise persons and departments with the best implementation, and allocate time and funds for ongoing training and improvement of existing programs.

Otherwise, you might end up in a pinch…

Here’s a Band-Aid for that Severed Limb!

You might have heard the old saw, ‘if there’s no time to do it right the first time, how are you going to find time to fix it later?’

Unfortunately, many companies appear to follow a different maxim – there’ll always be time to do it over.

Like our last reason, the problem is often financial. Momentary solutions that can be quickly applied to fix individual problems becomes the norm, despite the fact that the long term expense is much higher.

The best, most cost-effective solutions are applied right the first time and “solve” lots of problems by the fact that they prevent so many of them for happening. Then you don’t get into a situation where you’re spending a lot more to fix what could have been an easily avoided minor problem, but is now mission critical.

But that’s not going to help unless…

Training?  We Don’t Need no Stinking Training!

Proper ESD prevention is a team effort, but many companies underestimate the size of the team involved. As mentioned before, upper level management should take an interest in training, and in fact, every employee should be given at least a rudimentary class or video in how to follow the company’s practices.

It’s not enough to train the engineers of you haven’t informed the janitorial staff that cleans their sensitive work areas after they leave for the day how to properly do so.

Secretaries, interns, sales people – everyone who has the potential to walk into or affect an Electrostatic Protection Area (EPA) needs to know how to properly behave to minimize risk.

And finally…

We Only Use the Best – the Best We Can Afford, That Is.

Yes, it keeps coming back to price. But price should not be the only factor in deciding who to buy your ESD supplies from. Not all companies are created equally. Not all ESD products are held to the highest standard.

You want to find a vendor that can supply your ESD needs who can guarantee all of their products are properly tested, meet or exceed industry standards, and have the certification to prove it.

Always be sure to properly vet your chosen vendor, making sure they meet these requirements and be willing to ask for clients you can speak to and recommendations you can verify. If they’re reputable, they’ll be more than willing to have you check them out with their existing happy clients.

ESD prevention is no casual task. Your company may not have the risk of ending 36 lives, but putting best practices into place can certainly save jobs, computers and your clients.

We’d love to be the experts you can count on for your full service, seamless ESD solutions. For more information or advice on your specific ESD prevention needs – or any other ESD questions, please contact us today.

05 Apr

The Truth About 11 Myths of Electrostatic Discharge: Part 2

11 Myths of Electrostatic Discharge

Last week we shared with you Part 1 of The Truth About 11 Myths of Electrostatic Discharge; here’s Part 2…

Myth #6 – An ESD bag is all the protection I need.

There is a somewhat popular belief that you can use the ESD shielding bag that your circuit board or sensitive electronics was shipped in as adequate “matting” when you are working. This could not be more false.

Regardless of which ESD shielding bag you receive or purchase, it ONLY provides ESD protection while the item in entirely enclosed inside a sealed bag. Outside of the bag, it can actually increase the chances that you will generate an ESD event, because the bag is designed to “push” a charge away from the contents of the bag – right into your electronics.

Myth #7 – Grounded metal offers a safe haven from ESD.

In fact, conductive materials – like metals – are not safe surfaces for sensitive electronic components that could be subject to an electrostatic charge, even if they are grounded. In fact, the charge dissipation is so fast, the resistance to ground has almost zero impact.

The point of grounding is to get everything at the same potential energy level so that current from an ESD can’t flow where it shouldn’t.  Using metal, even grounded metal, voids this effort.

The next three myths are similar in nature…

Myth #8 – Circuit boards without complementary metal oxide semi-conductor (CMOS) are safe.

On its face, this seems obvious, as it is hard to find a circuit board without some CMOS components. However, ALL circuit boards are susceptible to electrostatic discharges and the damage they can cause.

Myth #9 – A printed wiring board (PWB) permanently protects a circuit board.

Just because a component is inserted into a PWB, that does not protect it from potential ESD damage. It does decrease the likelihood that fatal loss will occur, as the voltage the entire board can sustain is increased.

But this is by no means a guarantee of safety. All proper precautions must be taken when handling sensitive electronics.

Myth #10 – Once products are mounted on circuit boards, ESD mishaps cannot occur.

This is similar to the above myth.  But unlike PWB boards, unprinted boards can actually leave sensitive components even more vulnerable because there is less resistance to slow the electrostatic discharge down.

 Myth #11 – Small companies cannot afford proper ESD protection.

On the contrary, small companies cannot afford not to have suitable ESD protocols and tools. The risk of damage and the costs associated with it are just too excessive not to invest in the proper implementation of an ESD protected workstation – even a portable one, if need be.

We recommend at a minimum, personal grounding wrist straps, dissipative ESD matting and grounding cables.

We would love to be your full service, seamless ESD solution provider, no matter what your size or budget.  Contact us today for more information.

29 Mar

The Truth About 11 Myths of Electrostatic Discharge

11 Myths of Electrostatic Discharge

Would it surprise you to know that a good portion of our modern world would be unable to function without the help of electrostatic discharges (ESD’s)?

No one seems to know quite how it happened, but in 1984, Scott M. Kunen applied for a patent for a “touch controlled switch” – a device he had developed to allow lamps to be turned on or off with the touch of a human hand.

Little did he know that less than a decade later, computer companies would begin adapting his technology, covering it with a variety of static controlling sheaths, creating the capacitive-touch screen, the basis for all modern smart phones, tablets and touch screen laptops.

So, here’s the truth about the myths of electrostatic discharge.

Myths About Electrostatic Discharge

Myth #1 – All ESD is bad.

The truth is, most people use ESD everyday to make phone calls, send text messages, and create emails. The touch controlled switch and the capacitive-touch screen both operate by transmitting small ESD charges from your body into the devices to signal turning a light on, or the letters or numbers desired.

Myth #2 – Electrostatic Discharge is a modern day problem.

Believe it or not, ESD and necessary precautions to prevent it are older than the United States. In the 1400’s, forts and places that stored or produced explosives, gun powder, and even sawdust could fall prey to horrible accidents, so early forms of ESD control were developed and implemented.

Except, of course, when the good guys needed to blow up the bad guys’ stash in a Hollywood movie.

Myth #3 – ESD problems are really quite rare.

In truth, because of the extremely low levels of ESD required to damage small electronics and the fact that damage isn’t always visible or catastrophic, we may never know just how prevalent ESD events are.

Visible static sparks generated by our bodies have to build up between 500-1000 volts, and it takes twice that charge to be felt.  Most sensitive electronics can be damaged by 100 volts or less.

And even if the device continues to function as expected, its life expectancy may be severely diminished and in some cases, latent failure can occur, causing even more damage.

Since we cannot fully prevent or even detect an ESD event, all precautions should be taken to avoid an accidental discharge.

Myth #4 – Discharging fingers and tools before using them is sufficient precaution against ESD mishaps.

Unless you are able to hold your body AND tool perfectly still, you can (and often do) build up a replacement charge that can be discharged into your electronics.

As mentioned above, because of the negligible amount of charge necessary to potentially damage the sensitive parts, you have no way of knowing you are not transmitting a dangerous ESD. It’s better to be safe than sorry.

We recommend that you always use personal wrist straps, dissipative mats and grounding cords for the best chance of circumventing ESD problems.

Myth #5 – You have to touch an item to transmit an ESD to it.

As mentioned above, it takes very little for the human body to build up an electrostatic discharge. Just the movement of lifting your foot off the ground can generate up to 1,500 volts.

And that generated charge can easily leap from your hand to your unprotected device inches away.

Stay tuned next week for Part 2 of The Truth About 11 Myths of Electrostatic Discharge…