Instructions for Use:
This Adapter is a UL approved instrument however it will not indicate:
1. Ground and neutral reversed.
2. More than one hot wire in outlet.
3. The quality of ground path.
4. Presence of multiple wiring errors.
- Use the Ground Plug Adapter ONLY with electrical
receptacles that have been previously tested using an approved circuit
tester complying with CSA and or UL standards.
- The Ground Plug Adapter is equipped with three
indicating lights. The ONLY indication that is acceptable for Ground
Plug Adapter use is with the two outer "CIRCUIT OK" lights
energized, i.e., Lights #1 and #3 ON, Light #2 OFF.
*----------CIRCUIT OK---------*
| Light #1 |
Yellow Light #2 |
Red Light #3 Clear |
If any other condition exists, do not use the receptacle
or the Ground Plug Adapter until tested and approved by a qualified
electrician. Examples of wiring defects are not limited to the conditions
described below.
1. OPEN GROUND WIRE - The equipment grounding conductor
is not complete.
2. REVERSE POLARITY - The hot and the neutral circuit
conductors are reversed.
3. OPEN HOT WIRE - The hot circuit conductor is open
from a blown fuse, tripped circuit breaker, switch off, broken wire,
etc.
4. OPEN NEUTRAL WIRE - The neutral circuit conductor
is open.
5. HOT AND GROUND REVERSED - The hot circuit conductor
and the grounding conductor are reversed.
6. HOT ON NEUTRAL AND HOT OPEN - The hot circuit conductor
is connected to neutral terminal and the hot terminal is unwired. |