The Ohm Metrics CM2015* dual conductor workstation monitor continuously checks two (2) operators and two(2) worksurface ground connections. The unit has a normal voltage of 200mV when wearing a wrist strap and 900mV is the maximum (open wrist strap condition). The CM2015 packaged in a stainless steel case with remote jacks.
Utilizing very precise, low-voltage, resistive loop technology, the CM2015 is an extremely sensitive and Reliable ground monitoring instrument that uses the operator's skin resistance to determine if the system is operating properly. Audible and visible alarms are trig-gered if the operator's resistance exceeds 10 or 35 me-gohm (selectable at factory with default of 35 megohm). Low resistance also triggers an alarm event. Each monitor uses the WB2500 series dual wire wrist strap and coil cord although other compatible wrist strap sets may be substituted. Dual conductor wrist straps enable efficient , accurate resistance monitoring and grounding redundancy.
Features:
Monitors the ground integrity of two operators / two dual wire wrist bands and work station mats.
Alarm Limits: Wrist strap low limit: 35 megohm
Wrist strap high limit: 1.8 megohm
Mat high limit: 3.5 megohm
Dimensions:
4” W x 3” D x 1” H
10.16 x 7.62 x 2.54 cm
WEIGHT
6.8 oz
Power Supply
120VAC—60hz, 9-15 Volts DC, 100-600 mA, 2.1mm center positive output
Unit monitoring capabilities
2 wrist straps/persons + 2 mats
Performance Specifications
Maximum operator voltage
(alarm condition)
900mV
Typical operator voltage
< 200mV
Maximum mat voltage
(alarm condition)
1.25V
Typical mat voltage
< 900mV
Maximum GND current
100μA
Maximum GND voltage
(alarm condition)
1mV
Maximum GND voltage
(open circuit condition)
50mV
Alarm Limits
Wrist strap high limit
35 megohm
Wrist strap low limit
1.8 megohm
Mat high limit
3.5 megohm
GND (tool) high limit
10Ω
Temperature limits
Environmental Operating Conditions
50° F (10°C) to 122° F (50°C)
Adjustments
No field serviceable components; see periodic verification tools