PAN-750 Anemometer

Measure air velocity and temperature of ionizers

  • Ergonomic pocket size housing with large dual LCD simultaneous display of Temperature and Air Velocity or Relative Humidity
  • Data Hold to freeze the displayed value
  • Records Min/Max readings
  • Built-in low friction vane wheel improves accuracy of air velocity in ft/min, MPH, m/s, km/h, and Knots
  • Built-in precision thin-film capacitance humidity sensor for fast response
  • Built in thermistor for ambient temperature measurements
  • High temperature measurements using Type K thermocouple
  • Defaults to last function when powered off
  • Auto power off 10 minutes after last key is pressed with disable feature
  • Low Battery and overrange indication
  • Complete with built-in Humidity sensor and Vane wheel, wrist strap, and 9V battery.
  • Extech does not offer a NIST traceable calibration certificate for this model.

The PAN-750 Anemometer is a battery operated instrument used to measure air velocities and temperature of ionizers. This instrument can also be used to measure wind velocities and check air conditioning and heating systems. This portable anemometer provides fast, accurate readings with digital readability and the convenience of a remote sensor. It provides simultaneous display of air velocity and temperature. Its large 1.4 inch (1999 count) LCD display has a contrast adjustment. The PAN-750 provides several operational features such as "Data Hold", Record, Recall MIN/MAX measurements, and selection of oF or oC. It comes equipped with a heavy duty rubber holster with stand for easy operation. One 9V battery is supplied.

SPECIFICATIONS:
Measuring Ranges:
80 to 4,925 ft/min
0.9 to 55.9 mph
0.6 to 48.6 knots
0.4 to 25.0 m.sec
1.4 to 90.0 kn/hr

2% velocity accuracy via low friction ball bearing vane wheel (2.83"D)

Temperature Ranges:
32.0 to 140.0ºF
0 to 60.0ºC

Accurate temperature measurements to 1.5ºF/0.8ºC

Input Power:
1 each 9v Battery or AC adapter (not included)

Memory:
Minimum and Maximum measurement record/recall and average readings

Controls:
DATA HOLD button, Recall MIN/MAX button, ºC/ºF button, Record, Unit

Size:
Anemometer Dimensions
Width: 2.9" (7.4 cm)
Depth: 1.3" (3.3 cm)
Length: 7.2" (18.3 cm)

Anemometer Weight:
16 ounces

Vane Probe Dimension:
Width: 2.75" (7.4 cm)
Depth: 1.25" (3.3 cm)
Length: 5.5" (18.3 cm)

Vane Probe Weight:
8 ounces

Sensor Cord:
Length: 44" (111.8 cm)

Features:
Data Hold plus Automatic shut off

Interface:
RS232 Serial Interface