Item Number
Q007

Use the Qube to ground Work Surfaces, Floor Mats, Equipment, Personnel, etc.
|
Q007 Ground Adapter Plug
This new dual socket Grounding Cube provides an ESD ground path to a
previously tested receptacle
- Provides two banana jack grounding ports
- Easy access grounding ports regardless of outlet orientation
- Low Cost
- Non-Flammable ABS plastic
- Currently available
Dimensions:
Length: 1.25" (3.175 cm)
Width: 1.00" (2.54 cm)
Height: 1.25" (2.54 cm)
Pre-test Outlets
Prior To installation, always test the electrical outlet in accordance with AN SI/ESD S6.1 Grounding Standard to
insure 1:
- The ground conductor is present
? - There are no electrical shorts to the ground conductor
? - The electrical outlet is properly wired
? - Ground conductor impedance to the distribution panel is less than 1 ohm
1This circuit test is easily perform ed with a PGT-161 SureTest Circuit Analyzer available from Prostat and other sources.
Use the Prostat Qube for Resistance to Ground
(RTG)M easurem ents as required by Industry
Standards such as ANSI/ESD S20.20 and IEC61340-5-1
S
 
|